Commonwealth Building, Boston, MA

The new Commonwealth Building sits among Kenmore Square below the iconic Citgo Sign, minutes away from Boston’s Fenway Park.  Stantec was responsible for the design of this new eight-story, ~130,000 square foot commercial building for Related Beal.  The building consisted of two levels of below-grade parking, ground floor retail space, seven levels of above-grade office, and a mechanical penthouse.

Code Red Consultants served as the code consultant on the project to Related Beal and developed a detailed code approach documenting compliance with the local building and fire codes and reviewed architectural plans for code compliance.

Code Red Consultants was also retained directly by Related Beal to develop a comprehensive NFPA 241, Construction Fire Safety Plan that ensured the fire safety of construction personnel, the fire department, and the surrounding community over the course of the project. Additionally, Code Red Consultants served as the Fire Stopping Special Inspector, ensuring the passive fire protection systems were appropriately selected and installed.  As the Smoke Control Special Inspector, we ensured that the new stair pressurization systems were designed, installed, and operated in accordance with the applicable codes and standards.

Location

Boston, Mass.

Size

130,000 SF

Cost

$60-64 million

Completion

January 2022

Photography Credit

Related Beal and Mark Woods

Commonwealth Building, Boston, MA

The new Commonwealth Building sits among Kenmore Square below the iconic Citgo Sign, minutes away from Boston’s Fenway Park.  Stantec was responsible for the design of this new eight-story, ~130,000 square foot commercial building for Related Beal.  The building consisted of two levels of below-grade parking, ground floor retail space, seven levels of above-grade office, and a mechanical penthouse.

Code Red Consultants served as the code consultant on the project to Related Beal and developed a detailed code approach documenting compliance with the local building and fire codes and reviewed architectural plans for code compliance.

Code Red Consultants was also retained directly by Related Beal to develop a comprehensive NFPA 241, Construction Fire Safety Plan that ensured the fire safety of construction personnel, the fire department, and the surrounding community over the course of the project. Additionally, Code Red Consultants served as the Fire Stopping Special Inspector, ensuring the passive fire protection systems were appropriately selected and installed.  As the Smoke Control Special Inspector, we ensured that the new stair pressurization systems were designed, installed, and operated in accordance with the applicable codes and standards.